PRODUCTS

Technology for Future

Product

SE-4HCN-50-F

Electrochemical HCN Sensor (0~50 ppm)

The SE-4HCN-50-F is an electrochemical sensor capable of highly accurate detection of hydrogen cyanide (HCN) gas in the range of 0 to 50 ppm.
It is compatible with both fixed and portable devices and offers linear output with high resolution below 1 ppm.
The sensor is resistant to interference from major cross-sensitive gases such as carbon monoxide (CO), carbon dioxide (CO₂), nitric oxide (NO), and ethylene (C₂H₄), ensuring accurate measurement in complex gas environments.
It operates within a temperature range of -20℃ to +50℃ and offers a long lifespan of over 24 months under ambient air conditions.

KEY FEATURES
    • Measuring Range: 0~50 ppm
    • Sensitivity: 70±20 nA/ppm
    • Response Time: T90 < 90 seconds
    • Resolution: < 1 ppm
    • Sensor Life: More than 24 months in clean air
    • Operating Temperature: -20℃ to +50℃
    • Low Cross-Sensitivity: Minimal interference from CO, NO, CO₂, C₂H₄
Product Inquiry

SE-4HCN-50-F

Electrochemical HCN Sensor (0~50ppm)

DESCRIPTION

SE-4HCN-50-F is a high-precision electrochemical sensor capable of detecting hydrogen cyanide (HCN) gas within the 0–50 ppm range. It is suitable for both fixed and portable gas detection devices, providing linear output and high resolution below 1 ppm. It shows excellent selectivity by exhibiting minimal cross-sensitivity to interfering gases such as CO, NO, CO₂, and C₂H₄. Operating within a wide temperature range of -20℃ to +50℃, the sensor offers a long operating life of over 24 months in ambient air.


KEY FEATURES

- Measurement Range: 0–50 ppm
- Sensitivity: 70 ± 20 nA / ppm
- Response Time: T90 < 90 sec
- Resolution: < 1 ppm
- Operating Life: ≥ 24 months in ambient air
- Operating Temperature: -20℃ to +50℃
- Low cross-sensitivity to CO, NO, CO₂, C₂H₄


Product Specifications
Performance Characteristics
Output Signal70±20 nA / ppm
Typical Baseline Range (pure air, @ 20℃)≤ ±0.5 ppm HCN equivalent
Response Time (T90)< 90 seconds
Measurement Range0–50 ppm
Maximum Overload100 ppm
LinearityLinear
Repeatability< ±15% of signal
Recommended Load Resistor10 ohms
Resolution (Electronics Dependent)< 1 ppm typical
Bias VoltageNot required
Environmental
Temperature Range Continuous-20℃ to +50℃
Pressure Range800 to 1200 mbar
Operating Humidity Range15% to 90% RH
Lifetime
Long Term Output Drift< 10% per annum
Recommended Storage Temp0℃ to 20℃
Expected Operating Life> 24 months in air
Standard Warranty24 months from date of dispatch
Intrinsic Safety Data
Maximum at 100 ppm10 µA
Maximum o/c Voltage< 1.0 V
Maximum s/c Current< 0.1 A
Sensor Specifications
Accessories
Download
PDF
Datasheet
Download