PRODUCTS

Technology for Future

Product

Portable

SP-MGTP

Portable Multi-Gas Detector

The SP-MGTP is a sampling-type multi-gas detector capable of monitoring up to 6 gases with 37 possible gas combinations, including Volatile Organic Compounds (VOC). It continuously detects oxygen (O₂), toxic, flammable gases, and VOCs, providing real-time alerts through LED indicators, sound alarms, and vibration signals. Designed to prevent industrial accidents caused by hazardous gas exposure, this device offers reliable protection in demanding environments.

KEY FEATURES
    • Multi-gas Detection: Comprehensive monitoring of multiple gases.
    • Sampling Type with Embedded Pump & Probe: Accurate gas sampling in various environments.
    • Real-time Monitoring: Instant feedback on gas concentrations.
    • IP67 Rating: Water and dustproof for rugged use.
    • High-performance Alarms: Visual, audible, and vibration alerts.
    • Event Log: Records up to 30 events for easy tracking.
    • IrDA Communication: Easy data transfer and management.
    • Single Docking Station: Convenient for bump testing and calibration.
    • Explosion-proof Certification: Complies with global safety standards.
    • Pump Blockage Alarm: Alerts for pump blockages.
    • Filter Contamination Check: Visual inspection for filter status.
    • Three-button Operation: Simple and user-friendly controls.
Product Inquiry

SP-MGTP (Pump)

Sampling-Type Multi-Gas Detector for Up to 6 Gases

DESCRIPTION

The SP-MGTP is a sampling-type multi-gas detector designed to monitor up to six gases simultaneously. It is specifically engineered to detect the gases most commonly associated with industrial accidents, including those that cause oxygen deficiency, toxic gas poisoning, and the risk of gas explosions. This device can monitor up to six gases with 37 possible combinations of toxic and flammable gases. The concentrations of these gases are continuously displayed, and the detector activates visual, audible, and vibrating alarms when dangerous levels are detected, ensuring immediate alerts for safety.


KEY FEATURE

- Multi-gas Detection for Comprehensive Monitoring: Detects up to 6 gases with 37 possible combinations, offering versatile applications for monitoring a wide range of industrial environments.
- Sampling Type with Embedded Pump & Probe: Ensures accurate and reliable gas sampling for continuous monitoring in diverse environments.
- Real-time Monitoring for Immediate Results: Provides continuous gas concentration readings, delivering immediate feedback on environmental conditions.
- Water and Dustproof (IP67 Rating): Designed to endure rugged environments, offering reliable performance in harsh conditions.
- High-performance Alarms: Includes visual, audible, and vibrating alarms to immediately alert users to hazardous gas levels.
- Event Log for Easy Tracking: Automatically records recent events, including bump tests and calibrations, allowing for efficient tracking and maintenance.
- IrDA Communication: Simplifies configuration and data management with infrared communication.
- Single Docking Station: Provides a convenient docking station for easy bump testing and calibration, improving operational efficiency.
- Explosion-proof Certification: Complies with global explosion-proof standards, ensuring safe use in hazardous environments worldwide.
- Pump Blockage Alarm: Alerts users to any pump blockage, maintaining consistent and reliable operation.
- Filter Contamination Check: Enables users to visually inspect the filter status, ensuring proper operation and maintenance.
- Three-button Operation: The device features three intuitive buttons for easy and convenient operation.


DIMENSION



71468bf5a81bd331dc42e0e5d793be98_1743668878_4065.jpg

Product Specifications
Model SP-MGTP
Display LCD display with backlight for clear visibility in various lighting conditions
Indicator LEDs for status and alarm notifications
Keys 3 operational and programming keys for intuitive navigation and setup
Sensors Electrochemical Sensors: For toxic gases and oxygen (O₂) detection
PID (Photoionization Detector): For precise VOC (Volatile Organic Compound) detection
Catalytic Sensors: For combustible gas detection
NDIR (Non-Dispersive Infrared) Sensors: For monitoring combustible gases
Alarms Visual: LCD alarm display with backlight and indicator LEDs for clear alerts
Audible: 90 dB buzzer at 10 cm for immediate sound warnings
Vibration: Vibration alert for hazardous gas detection
Dimensions 77 mm (W) x 146 mm (H) x 43 mm (D)
Weight 490 g
Mounting Method Integrated belt clip for easy attachment and hands-free use
Operating Temperature Range -20°C to +50°C
Operating Humidity Range 10% to 90% RH (Non-condensing)
IP Rating IP67 (Fully dustproof and water-resistant for enhanced durability in harsh environments)
Environment Pressure Range 80 kPa to 120 kPa (Suitable for use in environments with this pressure range)
Sampling Type Built-in pump for efficient and accurate gas sampling
Battery Type Rechargeable Li-ion power supply (4,000 mAh) for extended operational time
Operating Time SP-MGTP-P0 Series: Approximately 30 hours of continuous use
SP-MGTP-N0/N1/N2 Series: Up to 5 days or more, depending on usage and settings
Enclosure Material TPU-coated polycarbonate (PC) for enhanced durability in tough conditions
IR-Link For seamless data management and easy configuration
Flow Rate 250 to 300 cc/min for consistent and accurate gas sampling
Warranty 2 years from the date of purchase
Sensor Specifications

Sensor Configuration

The SP-MGTP is equipped with four sensor slots, providing versatile and customizable gas detection capabilities. This modular design allows for the combination of different gas sensors to meet specific monitoring requirements. Below is a detailed list of the available sensors for each slot, enabling a wide range of configurations tailored to diverse industrial and safety applications.


Model Name Slot 1 (Fixed) Slot 2 (Fixed) Slot 3 (Optional Gas 1) Slot 4 (Optional Gas 2)
SP-MGTP-P-4O₂ (Oxygen)CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide)CH₄ (Catalytic)-
SP-MGTP-P-5-PIDO₂ (Oxygen)CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide)CH₄ (Catalytic)PID (VOC Detection)
SP-MGTP-P-5-SO₂O₂ (Oxygen)CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide)CH₄ (Catalytic)SO₂ (Sulfur Dioxide)
SP-MGTP-P-5-Cl₂O₂ (Oxygen)CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide)CH₄ (Catalytic)Cl₂ (Chlorine)
SP-MGTP-P-5-NH₃O₂ (Oxygen)CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide)CH₄ (Catalytic)NH₃ (Ammonia)
SP-MGTP-P-5-H₂O₂ (Oxygen)CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide)CH₄ (Catalytic)H₂ (Hydrogen)
SP-MGTP-P-5-NO₂O₂ (Oxygen)CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide)CH₄ (Catalytic)NO₂ (Nitrogen Dioxide)
SP-MGTP-P-5-HFO₂ (Oxygen)CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide)CH₄ (Catalytic)HF (Hydrogen Fluoride)
SP-MGTP-P-5-HCNO₂ (Oxygen)CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide)CH₄ (Catalytic)HCN (Hydrogen Cyanide)
SP-MGTP-P-5-HClO₂ (Oxygen)CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide)CH₄ (Catalytic)HCl (Hydrochloric Acid)
SP-MGTP-P-5-NOO₂ (Oxygen)CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide)CH₄ (Catalytic)NO (Nitric Oxide)
SP-MGTP-P-5-H₂O₂O₂ (Oxygen)CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide)CH₄ (Catalytic)H₂O₂ (Hydrogen Peroxide)
SP-MGTP-N-4O₂ (Oxygen)CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide)CH₄ (IR)-
SP-MGTP-N-5-PIDO₂ (Oxygen)CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide)CH₄ (IR)PID (VOC Detection)
SP-MGTP-N-5-SO₂O₂ (Oxygen)CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide)CH₄ (IR)SO₂ (Sulfur Dioxide)
SP-MGTP-N-5-Cl₂O₂ (Oxygen)CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide)CH₄ (IR)Cl₂ (Chlorine)
SP-MGTP-N-5-NH₃O₂ (Oxygen)CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide)CH₄ (IR)NH₃ (Ammonia)
SP-MGTP-N-5-H₂O₂ (Oxygen)CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide)CH₄ (IR)H₂ (Hydrogen)
SP-MGTP-N-5-NO₂O₂ (Oxygen)CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide)CH₄ (IR)NO₂ (Nitrogen Dioxide)
SP-MGTP-N-5-HFO₂ (Oxygen)CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide)CH₄ (IR)HF (Hydrogen Fluoride)
SP-MGTP-N-5-HCNO₂ (Oxygen)CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide)CH₄ (IR)HCN (Hydrogen Cyanide)
SP-MGTP-N-5-HClO₂ (Oxygen)CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide)CH₄ (IR)HCl (Hydrochloric Acid)
SP-MGTP-N-5-NOO₂ (Oxygen)CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide)CH₄ (IR)NO (Nitric Oxide)
SP-MGTP-N-5-H₂O₂O₂ (Oxygen)CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide)CH₄ (IR)H₂O₂ (Hydrogen Peroxide)
SP-MGTP-N-5-CO₂O₂ (Oxygen)CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide)CO₂ (IR) + CH₄ (IR)-
SP-MGTP-N-6-PIDO₂ (Oxygen)CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide)CO₂ (IR) + CH₄ (IR)PID (VOC Detection)
SP-MGTP-N-6-SO₂O₂ (Oxygen)CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide)CO₂ (IR) + CH₄ (IR)SO₂ (Sulfur Dioxide)
SP-MGTP-N-6-Cl₂O₂ (Oxygen)CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide)CO₂ (IR) + CH₄ (IR)Cl₂ (Chlorine)
SP-MGTP-N-6-NH₃O₂ (Oxygen)CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide)CO₂ (IR) + CH₄ (IR)NH₃ (Ammonia)
SP-MGTP-N-6-H₂O₂ (Oxygen)CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide)CO₂ (IR) + CH₄ (IR)H₂ (Hydrogen)
SP-MGTP-N-6-NO₂O₂ (Oxygen)CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide)CO₂ (IR) + CH₄ (IR)NO₂ (Nitrogen Dioxide)
SP-MGTP-N-6-HFO₂ (Oxygen)CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide)CO₂ (IR) + CH₄ (IR)HF (Hydrogen Fluoride)
SP-MGTP-N-6-HCNO₂ (Oxygen)CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide)CO₂ (IR) + CH₄ (IR)HCN (Hydrogen Cyanide)
SP-MGTP-N-6-HClO₂ (Oxygen)CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide)CO₂ (IR) + CH₄ (IR)HCl (Hydrochloric Acid)
SP-MGTP-N-6-NOO₂ (Oxygen)CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide)CO₂ (IR) + CH₄ (IR)NO (Nitric Oxide)
SP-MGTP-N-6-H₂O₂O₂ (Oxygen)CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide)CO₂ (IR) + CH₄ (IR)H₂O₂ (Hydrogen Peroxide)


Applicable Sensor Specifications

The SP-MGTP ioffers a wide range of gas sensors, each designed to meet specific detection needs across various environments. Each sensor is engineered with distinct measuring ranges, resolutions, and alarm thresholds to provide reliable and accurate detection. Below are the specifications for the available sensors:


Gas Sensor Type Measuring Range Resolution Low Alarm High Alarm
Oxygen (O₂)Electrochemical0 ~ 30 %vol0.1 %vol19 %vol23 %vol
Carbon Monoxide (CO)Electrochemical0 ~ 1000 ppm1 ppm30 ppm60 ppm
Hydrogen Sulfide (H₂S)Electrochemical0 ~ 200 ppm0.1 ppm10 ppm15 ppm
Methane (CH₄)Catalytic / NDIR0 ~ 100 %LEL1 %LEL10 %LEL30 %LEL
Carbon Dioxide (CO₂)Non-Dispersive Infrared (NDIR)0 ~ 5 %vol0.01 %vol0.5 %vol1.0 %vol
Ammonia (NH₃)Electrochemical0 ~ 100 ppm1 ppm25 ppm35 ppm
Sulfur Dioxide (SO₂)Electrochemical0 ~ 20 ppm0.1 ppm2 ppm5 ppm
Hydrogen (H₂)Electrochemical0 ~ 1000 ppm1 ppm100 ppm500 ppm
Nitrogen Dioxide (NO₂)Electrochemical0 ~ 20 ppm0.1 ppm3 ppm5 ppm
Chlorine (Cl₂)Electrochemical0 ~ 10 ppm0.1 ppm1 ppm2 ppm
Hydrogen Fluoride (HF)Electrochemical0 ~ 10 ppm0.1 ppm0.5 ppm1.0 ppm
Hydrogen Cyanide (HCN)Electrochemical0 ~ 50 ppm0.1 ppm10 ppm20 ppm
Hydrogen Chloride (HCl)Electrochemical0 ~ 50 ppm0.1 ppm5 ppm10 ppm
VOC (PID)Photoionization Detector (PID)0 ~ 4000 ppm1 ppm50 ppm200 ppm
Nitric Oxide (NO)Electrochemical0 ~ 500 ppm0.5 ppm
Hydrogen Peroxide (H₂O₂)Electrochemical0 ~ 100 ppm0.1 ppm
Download
FW
SP-MGTP Firmware(v2072)
Download
PDF
Manual
View in More Languages
PDF
Datasheet
View in More Languages